Succinic anhydride is the smallest anhydride in ordinary industrial use and the one with the highest anhydride content: C4H4O3, 100.07 g/mol, 71.97% of its mass is the anhydride group. It is a white flake solid melting at 118 to 121 deg C, and it is bought in far larger tonnage for what the ring does when it is opened by an alcohol or an amine than for what it does as an epoxy hardener.
That split matters commercially. Succinic anhydride is a commodity intermediate with many producers and a published price that moves with succinic acid; it is not a specialty hardener, and a page about it should not pretend otherwise. What a buyer actually needs to know is narrower and harder: whether the lot in front of them is succinic anhydride at all – the CAS number is one digit from maleic anhydride – whether the flake is dry, and what the dose is if the ring is going to be used against an epoxy.
Why 72% Anhydride Content Changes Everything
A hardener’s dose is set by its equivalent weight, and the equivalent weight of an anhydride rests on how much of the molecule is anhydride. In the bicyclic family that fraction is around 43 to 48% because most of the mass is hydrocarbon ring. In succinic anhydride it is 71.97%, because the molecule is nothing but an anhydride ring and two methylenes.
| Anhydride | Formula | MW | Anhydride group content | Working AEW | phr at EEW 185, r 0.90 |
|---|---|---|---|---|---|
| Succinic anhydride, 99.5% | C4H4O3 | 100.07 | 71.97% | 100.6 | 48.9 |
| THPA, 85-43-8 | C8H8O3 | 152.15 | 47.34% | 152.15 | 74.0 |
| HHPA, 85-42-7 | C8H10O3 | 154.16 | 46.72% | 154.16 | 75.0 |
| MTHPA, 41.0% min | C9H10O3 | 166.17 | 43.34% theoretical | 175.7 | 85.4 |
| MNA, 98% | C10H10O3 | 178.18 | 40.42% theoretical | 181.8 | 88.5 |
Turned into equivalents per kilogram, which is how a drum should be compared with another drum: succinic anhydride carries 9.94 anhydride equivalents per kilogram against 6.57 for THPA and 5.50 for MNA. A tonne of succinic anhydride does the stoichiometric work of one and a half tonnes of tetrahydrophthalic anhydride.
The consequence on the plant floor is heat, not economy. The same equivalents arrive in less mass and with a smaller heat sink, so the exotherm per unit volume of mix is concentrated into a shorter gel. A 48.9 phr hardener dose also means a leaner, harder, more crosslinked network between junctions – the cured part is stiffer and more heat resistant, and distinctly more brittle, because the chain segment between crosslinks is three methylenes long.
Chemical and Physical Properties
| Property | Value | Note |
|---|---|---|
| CAS | 108-30-5 | Oxolane-2,5-dione |
| Formula | C4H4O3 | 100.07 g/mol |
| Anhydride groups | 1 | C2O3 = 72.02 of 100.07 = 71.97% |
| Appearance | White flake solid | Flake, not powder, in standard supply |
| Melting point | 118 to 121 deg C | Identity check and blend check |
| Assay | 99.5% min | Total anhydride by titration |
| Theoretical acid value | 1121.4 mg KOH/g | Highest in the family |
| Theoretical iodine value | 0 | No double bond – a free purity check |
| PubChem CID | 7922 | InChIKey RINCXYDBBGOEEQ-UHFFFAOYSA-N |
Identity: Melting Point First, Iodine Value Second
The expensive mistake with this product is a purchase order typed one digit wrong. Succinic anhydride is 108-30-5; maleic anhydride is 108-31-6. Both are five-membered cyclic anhydrides, both are sold as flake or briquette, both are described as white to off-white solids, and they do not do the same thing – maleic anhydride carries a carbon-carbon double bond that copolymerises, Diels-Alder reacts and discolours.
| Product | CAS | Melting point | Theoretical iodine value | Double bond |
|---|---|---|---|---|
| Succinic anhydride | 108-30-5 | 118 to 121 deg C | 0 | None |
| Maleic anhydride | 108-31-6 | 52 to 54 deg C | 258.8 | One |
| Glutaric anhydride | 108-55-4 | 55 to 57 deg C | 0 | None |
| Succinic acid | 110-15-6 | 182 to 185 deg C | 0 | None |
The melting point separates all four in one measurement, and it needs no equipment beyond a capillary tube. Succinic acid reads high because it is a diacid, not an anhydride; maleic and glutaric anhydride both read low. A lot that melts below 118 deg C contains a lower-melting anhydride, and the titration assay will not necessarily catch it, because an assay for total anhydride counts maleic anhydride as anhydride.
The iodine value is the second, independent check, and it is free, because the theoretical value for succinic anhydride is zero. Every 1% of maleic anhydride blended in adds about 2.59 to the iodine value:
| Maleic anhydride in the lot | Iodine value increase | Expected melting range |
|---|---|---|
| 0% | 0 | 118 to 121 deg C |
| 1% | +2.59 | Depressed at the lower bound |
| 5% | +12.9 | Clearly below the specification |
| 10% | +25.9 | Not sellable as succinic anhydride |
For a product where a single digit separates it from a chemical with completely different reactivity, these two tests are the cheapest quality system available. Ask for melting range and iodine value on the certificate, not assay alone.
Hydrolysis: The Fastest in the Family
Succinic anhydride opens faster than any of the bicyclic anhydrides. Two things drive it: the five-membered ring is strained and opens readily, and the flake form presents a large surface area to humid air, so a bag that is opened and left open hydrolyses from the surface inward before the core has changed at all.
| Water in the lot | Succinic anhydride destroyed | Succinic acid formed | Free acid reading |
|---|---|---|---|
| 0.01% (100 ppm) | 0.56 kg/t | 0.66 kg/t | +0.066 points |
| 0.05% (500 ppm) | 2.8 kg/t | 3.3 kg/t | +0.33 points |
| 0.10% (1 kg/t) | 5.6 kg/t | 6.6 kg/t | +0.66 points |
The striking figure in that arithmetic is the ratio: 180 kg of water will consume a full tonne of succinic anhydride, because the molecule is small. Nothing about the product is more sensitive to housekeeping than this. Free acid percent as succinic acid (118.09) equals acid value in mg KOH/g multiplied by 0.1052 – the lowest multiplier in the anhydride family, which is exactly why a succinic anhydride free acid figure always looks harmless next to a tetrahydrophthalic one for the same amount of damage.
Where Succinic Anhydride Actually Goes
Only a minority of the tonnage becomes an epoxy hardener. The larger uses are ring-opening reactions onto something other than an epoxy:
- Polyester and alkyd branching. The anhydride opens onto hydroxyl-functional resin intermediates to add acid functionality and branching without adding a diol. Succinate half-esters appear in powder coatings, can coatings and industrial stoving enamels.
- Succinimide and succinate intermediates. The base for agrochemical and pharmaceutical intermediates, lubricant additives and corrosion inhibitors; the ring opens cleanly with amines and alcohols under mild conditions, which is what makes it a good building block.
- Surface modification. Esterification of starch, cellulose and mineral fillers to change hydrophobicity, flow and compatibility.
- Curing and crosslinking agent in alkyd, unsaturated polyester and some adhesive systems, where acid functionality has to be introduced at moderate temperature.
- Electrolyte additive research. Reported in lithium-ion literature as a film-forming additive; treat this as a development area and qualify cell-grade purity separately rather than assuming an industrial grade will do.
- Epoxy hardener or co-hardener – the use this page’s readers usually start from, and the one that needs the most care. See below.
Succinic Anhydride in Epoxy Systems
Three facts make it a co-hardener more often than a sole hardener. The melting point of 118 to 121 deg C means the hardener has to be melted or dissolved before it can be mixed, so the process runs hot from the start. The dose of 48.9 phr at EEW 185 and r 0.90 is a third lower than a tetrahydrophthalic system, which concentrates the exotherm. And the cured network is short and brittle, with three methylenes between crosslinks.
Where it earns its place:
- Powder coatings and laminating systems. Processes already running above 120 deg C, where a solid hardener is an advantage rather than an obstacle.
- Modifying hardener at 10 to 30 phr in a THPA or MTHPA system, to raise anhydride density, shorten gel time and stiffen the cured part. The blend equivalent weight is a harmonic mean, so it moves further than the weight fraction suggests: 10 phr of succinic anhydride in MTHPA at 175.7 gives a blend AEW of about 163.5, a 7% dose change that has to be calculated rather than estimated.
- Powder and moulding compounds where the hardener is pre-blended dry, and the hydrolysis risk is managed by keeping the whole compound dry.
Where it does not: a large filled casting, a room-temperature system, or any process where toughness matters more than heat resistance. A diol or a flexibiliser belongs in those formulations, not a shorter anhydride.
Storage: Caking Is the Failure Mode
The failure is quiet and starts at the surface. A bag of flake left open in a humid warehouse takes up water at the surface of every flake; the surface hydrolyses to succinic acid, which is hygroscopic and sticky, and the lot cakes into a block. The assay then reads a point or two low, the melting range sags, and the free acid figure – if anyone measures it – has moved.
Practical rules: keep the liner closed between charges, store below 30 deg C in a dry warehouse, do not store next to amines, alkalis, alcohols or oxidisers, and never reuse a drum that held an amine. A partly used bag should be resealed with the liner folded over rather than rolled, and a lot that has caked should be re-tested rather than broken up and used. Melts must be held dry and not overheated; the free acid climbs steadily in a hot open vessel.
Dust is irritating to eyes and respiratory tract and the solid is corrosive on moist skin. Local exhaust ventilation at the charging point, gloves, eye protection and a dust mask. Absorb spills dry, do not wash into a drain, and never seal a wet spill in a closed container.
Buying Checklist
- Melting range, not just assay. 118 to 121 deg C is the identity and the blend check in one number.
- Iodine value. Theoretical zero; anything above a few points means unsaturated anhydride in the lot.
- Free acid or moisture. Convert between them at 0.1052 for free acid from acid value, or about 0.66 points of free acid per 0.1% water.
- Appearance and flowability. Caked or sticky flake has already taken up water, whatever the assay says.
- Liner and bag construction. Polyethylene-lined, sealed; the liner is the moisture barrier and it is the first thing to be skipped.
- Grade statement. Industrial versus a food-contact or cell-grade qualification – do not assume the industrial grade carries either.
FAQ
Is succinic anhydride the same as maleic anhydride?
No. Succinic anhydride is 108-30-5 and saturated; maleic anhydride is 108-31-6 and carries a double bond. The melting points are 118 to 121 deg C against 52 to 54 deg C, and the iodine values are 0 against 258.8. The CAS numbers differ by one digit, which is exactly why both tests belong on the certificate.
Why is the epoxy dose so much lower than other anhydrides?
Because 72% of the molecule is the anhydride group. Working AEW is 100.6 g/eq, so at EEW 185 and r 0.90 the dose is 48.9 phr against 74.0 for THPA. The equivalent count per kilogram is 9.94 against 6.57.
Can it be the only hardener in a casting?
It can be made to work, but the cured network is brittle and the melting point forces a hot process, so most formulators use it as a co-hardener or in powder systems. If toughness matters, pair it with a flexibiliser or use a longer-chain anhydride.
Why does the melting point matter more than the assay?
Because a titration for total anhydride cannot distinguish succinic anhydride from maleic anhydride, and both are white solids sold in flake. The melting point separates them in one measurement, and a melting range that sags below 118 deg C is the first visible sign of a blend.
How fast does it hydrolyse in storage?
Faster than the bicyclic anhydrides, and from the surface inward. 180 kg of water would consume a full tonne, so a sealed liner matters more than a dry-looking room. Store below 30 deg C, keep the bag closed, and re-test a lot that has caked rather than using it.
Is succinic anhydride food grade?
Succinic acid has food uses; succinic anhydride is an industrial intermediate and is supplied against industrial specifications. If a food-contact application is intended, state it at enquiry and expect a separate qualification.
References and Further Reading
- CAS 108-30-5: oxolane-2,5-dione; PubChem CID 7922; InChIKey RINCXYDBBGOEEQ-UHFFFAOYSA-N; C4H4O3, 100.07 g/mol.
- Anhydride basis: C2O3 = 72.02 g/mol; 72.02 / 100.07 = 71.97%; working AEW at 99.5% assay = 100.6 g/eq; theoretical acid value 1121.4 mg KOH/g.
- Hydrolysis basis: succinic anhydride + H2O gives succinic acid at 118.09 g/mol; 1 kg of water per tonne consumes 5.6 kg of anhydride and yields 6.6 kg of acid, a free acid rise of 0.66 points.
- Iodine value basis: 253.81 g/mol for I2; maleic anhydride (98.06 g/mol, one double bond) has a theoretical iodine value of 258.8, so 1% blended in adds 2.59.
- PolyBlueChem: succinic anhydride product page; succinic, maleic and glutaric anhydride compared; anhydride dosage in phr.
- PolyBlueChem: alkenylsuccinic anhydrides: chain length, dose and identity – the substituted succinic anhydrides, where the chain rather than the ring sets the dose.
- PolyBlueChem: free acid, colour and storage of acid anhydrides; THPA properties and grades.
Contact PolyBlueChem for a current certificate of analysis, a sample for qualification, and a quotation for bag, big-bag or drum supply.