Urea SCR Dosing: Stoichiometry, AdBlue Consumption, Deposits

What the Exhaust System Does With the Urea

Selective catalytic reduction turns nitrogen oxides back into nitrogen and water by reacting them with ammonia over a catalyst. The ammonia is not carried on the vehicle as ammonia; it is made on board from a urea solution, which is safe to store, non-toxic at the concentrations used, and easy to dispense. Everything that can go wrong with AdBlue in service follows from that design choice: the urea has to be converted cleanly, at the right rate, in a very short distance and over a wide range of exhaust temperatures.

This article covers the chemistry, the stoichiometry behind the dosing rate, and the deposit mechanisms that decide whether a truck runs to its next service interval without a derate.

The Three Steps From Urea to Ammonia

The conversion is a sequence, and each step has a temperature window and a failure mode.

Step Reaction Conditions If it goes wrong
1. Evaporation Droplet of solution loses water Hot exhaust gas, good atomisation Wet wall, incomplete evaporation, urea crystallises
2. Thermolysis CO(NH2)2 -> NH3 + HNCO Above roughly 150 to 200 deg C Incomplete decomposition leaves solid urea or cyanuric acid
3. Hydrolysis HNCO + H2O -> NH3 + CO2 Catalytic surface, above about 200 deg C Isocyanic acid escapes and polymerises downstream

The stoichiometry of the sequence is the reason urea was chosen. One mole of urea releases one mole of ammonia in thermolysis and a second mole in hydrolysis, so one mole of urea delivers two moles of ammonia. That factor of two is the whole basis of the dosing calculation.

The Stoichiometry, Worked Out

The reduction reactions consume ammonia and nitrogen oxides in a one-to-one ratio:

Standard SCR: 4 NH3 + 4 NO + O2 -> 4 N2 + 6 H2O

Fast SCR: 2 NH3 + NO + NO2 -> 2 N2 + 3 H2O

In both cases one mole of ammonia removes one mole of nitrogen oxide. When nitrogen oxides are expressed as NO2 equivalent, the mass balance gives a single number worth remembering:

Quantity Calculation Result
Ammonia per kilogram of urea 2 x 17.03 / 60.06 0.567 kg NH3, about 33.3 mol
NOx (as NO2) removable per kilogram of urea 33.3 mol x 46.01 g/mol 1.53 kg NOx
Urea in one litre of AUS 32 1.09 kg/L x 32.5% About 354 g
NOx removable per litre of AUS 32 0.354 kg x 1.53 About 0.54 kg NOx

That last figure is the theoretical ceiling. A litre of AdBlue can neutralise about half a kilogram of nitrogen oxides and no more, because the chemistry stops there. Real consumption is higher than the theoretical figure, and the gap between theory and practice is where most of the engineering lives.

Why Real Consumption Is Two to Three Times the Minimum

Take a heavy-duty diesel engine before aftertreatment with nitrogen oxide emissions of roughly 5 to 7 g/kWh and a fuel consumption of about 200 g/kWh. That is roughly 25 to 35 g of nitrogen oxides per kilogram of fuel burned, which by the stoichiometry above needs about 16 to 23 g of urea, or roughly 1.6 to 2.3% of the fuel mass, and therefore about 1.2 to 1.8 litres of AdBlue per 100 litres of diesel.

Observed consumption on the road is usually 3 to 5 litres per 100 litres. The difference has four identifiable causes:

  • Ammonia slip. The system deliberately runs slightly ammonia-rich to keep NOx conversion high, and the unreacted ammonia is either oxidised in a downstream catalyst or lost. Every percent of slip is urea paid for and not used.
  • Incomplete conversion. Below the light-off temperature the catalyst does not reach full conversion, and cold starts, urban duty cycles and short journeys spend a disproportionate amount of time below it.
  • Non-ideal mixing. Ammonia has to be distributed uniformly across the face of the catalyst. Maldistribution means local over- and under-dosing at the same time, and the average has to be pushed up to keep the worst spot compliant.
  • Concentration and quality errors. Fluid that is weaker than 32.5% delivers less ammonia per litre, and the closed-loop control compensates by dosing more volume rather than by raising the concentration, which is one reason a diluted batch can look acceptable on consumption figures while quietly over-working the pump.

Deposits: The Real Cost of a Wrong Specification

Deposits are the most common field failure in urea SCR, and they have four distinct chemical origins. Recognising which one is present tells you whether the problem is the fluid, the dosing strategy or the hardware.

Deposit Chemical origin Where it forms Usual root cause
Solid urea Unevaporated solute Injector tip, pipe walls, mixer Poor atomisation, cold exhaust, impingement on a wall
Biuret Thermal dimerisation of urea in the solid or in a hot spot Mixer, upstream catalyst face Biuret above specification in the fluid
Cyanuric acid and higher condensates Overheating of urea or isocyanic acid Hot surfaces, injector boss Hot shutdown, poor cooling of the injector, incorrect dosing near a hot surface
Phosphate and calcium scale Precipitation from impurities in the fluid Injector, mixer Water quality, raw material quality, storage contamination

The first and third rows are mostly hardware and control issues. The second and fourth are specification issues, and they are the ones a buyer of raw material actually controls. A fluid made from urea at the biuret limit, dissolved in water that was not demineralised, will deposit slowly and then fail suddenly, and neither the driver nor the workshop will connect the failure to the drum the fluid came from.

Why the deposit problem is cumulative

None of these deposits form in a single event. Each one accumulates a few micrometres at a time, changing the spray pattern slightly, which changes the evaporation slightly, which deposits a little more. By the time the vehicle reports a fault, the cause was in the fluid months earlier. This is the reason the AdBlue specification is written at the milligram level and the reason a blender’s water quality is part of the product specification rather than part of the plant’s housekeeping.

Ammonia Slip and the Downstream Catalyst

Because the dosing has to anticipate the NOx that is coming, and because the sensor is downstream of the reaction it is controlling, every urea SCR system overshoots some of the time. The unreacted ammonia is handled by an ammonia oxidation catalyst, which converts it to nitrogen or to nitrogen oxides depending on temperature and on the precious-metal loading.

The practical consequence for a buyer of raw material is indirect but real. A fluid that is off-concentration, or loaded with an impurity that deactivates the catalyst, shifts the operating point of the whole control loop. The system responds by dosing more, slip rises, the ammonia oxidation catalyst is asked to do more, and the fuel penalty and the deposit load both go up. A raw-material specification is a control-loop specification.

Temperature, Cold Start and the Minute of Worst Emissions

SCR catalysts need heat to work. Below roughly 200 deg C the conversion of nitrogen oxides is limited, and below the point at which urea decomposes cleanly the fluid can be sprayed onto a surface that is too cold to evaporate it. Modern systems deal with this by delaying dosing until the model says the exhaust is hot enough, which means the first minutes of a cold start are handled by the engine calibration rather than by the catalyst.

That is also why AdBlue consumption in urban delivery duty is proportionally higher than in long-haul duty: more cold starts, more time below light-off, and a larger fraction of the fluid spent on transients rather than on steady-state conversion.

Diagnosing a Deposit Complaint

A structured sequence saves the part-swapping that usually follows a first SCR fault.

  1. Check the fluid first, not last. Density or refractive index for concentration, biuret for thermal history, metals for contamination. A single off-spec batch explains a whole fleet’s complaints.
  2. Look at where the deposit is. Injector tip only points to atomisation and cooling; mixer and upstream face points to the fluid or to the dosing map; downstream points to slip and to the ammonia oxidation catalyst.
  3. Ask for the duty cycle. Short urban journeys with frequent cold starts will deposit more than long haul on the same fluid, and no fluid specification can change that.
  4. Check the storage and transfer chain. A dedicated tank, a lined hose and a stainless or polyethylene transfer line are part of the product specification in practice, whatever the certificate says.
  5. Compare against a retained sample. If the blender kept a retained sample from the batch, the question of whether the fluid was in specification at the point of manufacture is settled in an afternoon instead of an argument.

What This Means When Buying Urea

Three purchasing decisions follow directly from the chemistry above.

Buy on biuret and metals, not on nitrogen. The nitrogen figure separates a conforming lot from a grossly off-spec one and tells you nothing about the two properties that cause deposits.

Treat the water as an ingredient. A blender who buys perfect urea and dissolves it in softened water has made a fluid that will scale an injector. Demineralised water, checked per batch, is not an optional cost.

Keep the batch traceable. The failure will appear months later on a vehicle that cannot tell you which drum it drank. A batch number on the certificate and on the tank log is the only way back.

FAQ

How much AdBlue does a truck use per 100 litres of diesel?

Typically 3 to 5 litres, depending on duty cycle, engine calibration and ambient temperature. The stoichiometric minimum is closer to 1.5 litres, so a vehicle consuming much less than 3 litres per 100 litres is either doing very little high-load work or dosing less than the calibration intends.

Can a vehicle run without AdBlue?

Most modern systems will not let it. Once the tank is empty or the fluid is detected as out of specification, the engine control unit progressively limits torque and speed, and in many jurisdictions the vehicle is not legally compliant. The limit strategy exists because a vehicle that can ignore the reagent cannot meet its NOx limit.

Does the concentration really matter that much?

Yes, in both directions. Weaker fluid delivers less ammonia and the system compensates by dosing more volume, which raises deposit risk and can exceed the pump’s design duty. Stronger fluid moves away from the eutectic and crystallises at higher temperatures.

What causes the white crust around the injector?

Almost always unevaporated urea or its thermal decomposition products, caused by impingement on a surface that is too cool, by a spray pattern that has drifted, or by a biuret level above specification. It is the earliest visible sign of a problem that will later become a fault code.

Is biuret harmful to the engine?

Not to the engine; to the aftertreatment. Biuret does not decompose to ammonia at exhaust temperatures, so it passes through as a solid and deposits on the mixer and the catalyst face. The engine notices only when the backpressure or the conversion efficiency changes.

Do all AdBlue brands perform the same?

If they all conform to the same quality requirement, yes in principle, and the differences that appear in the field usually trace back to water quality, storage materials, or to a batch that never met the requirement. The specification is only as good as the sampling behind the certificate.

Related Reading

Disclaimer: this article describes the chemistry and engineering of urea SCR at a general level. Engine calibration, approval requirements and warranty conditions are the responsibility of the vehicle manufacturer, and emission regulations differ by jurisdiction.

Contact PolyblueChem for AdBlue-grade urea, blends to an agreed AUS 32 specification, and certificates with the metals panel reported element by element.

Scroll to Top