What MTHPA Is, and Why One Methyl Group Changes the Calculation
4-Methyl tetrahydrophthalic anhydride (MTHPA, CAS 11070-44-3) is a cycloaliphatic dicarboxylic anhydride with the formula C9H10O3 and a molecular weight of 166.17 g/mol. Structurally it is tetrahydrophthalic anhydride with a methyl group added to the ring, and the commercial consequence of that methyl group is out of proportion to its size: it lowers the melting point from about 100 deg C to below room temperature, so MTHPA is sold and used as a liquid, and it raises the equivalent weight from 152.15 to 166.18, so the dose moves by about 15%.
Those two consequences are why MTHPA is the reference liquid anhydride for electrical casting, potting and encapsulation, and why a formulation transferred from a solid anhydride without recalculating is normally under-cured.
It is also the product most often confused with its neighbours. Three distinct materials are sold into the same applications and described with the same words: THPA (CAS 85-43-8, C8H8O3, 152.15, solid), 3,4,5,6-THPA (CAS 2426-02-0, also C8H8O3, 152.15, solid at 67 deg C, sometimes called TMMA) and MTHPA (CAS 11070-44-3, C9H10O3, 166.17, liquid). MTHPA is the only one of the three that is a liquid at room temperature, and it is the only one with a different molecular formula. The comparison table for the solid three is in THPA vs 3,4,5,6-THPA vs HHPA.
Chemical and Physical Properties
| Property | Value |
|---|---|
| CAS number | 11070-44-3 |
| CAS registry name | Tetrahydromethylphthalic anhydride |
| EINECS | 234-290-7 |
| Molecular formula | C9H10O3 |
| Molecular weight | 166.17 g/mol |
| Anhydride groups per molecule | 1 |
| Anhydride equivalent weight | 166.18 g/eq theoretical; about 175.7 g/eq at 41.0% anhydride group content |
| Theoretical anhydride group content | 43.34% (C2O3 = 72.02 g/mol) |
| Theoretical acid value | 675.4 mg KOH/g |
| Appearance at 25 deg C | Liquid, pale yellow to water-clear |
| Viscosity at 25 deg C | 30 to 50, or 50 to 70 mPa.s |
| Crystallisation point | 0 deg C max, or -15 deg C max |
| Ring double bond | One |
| Chemical family | Cycloaliphatic dicarboxylic anhydride, liquid |
The Chemistry Behind It
Isoprene, not butadiene
THPA is made by the Diels-Alder addition of butadiene to maleic anhydride. MTHPA is made the same way with isoprene in place of butadiene, which is why the molecule carries one methyl group on the ring and exactly one double bond. The reaction gives a mixture rather than a single compound, because isoprene is unsymmetrical and the dienophile can approach either end: the two principal products are the 3-methyl and the 4-methyl isomers.
That mixture is not a manufacturing defect that somebody forgot to fix. It is the commercial product, and the ratio between the isomers plus the amount of unreacted tetrahydrophthalic anhydride left in the lot is what decides whether the crystallisation point comes out at 0 deg C or at -15 deg C.
For the grades offered by PolyBlueChem the producer declares the methyl distribution at 3-methyl / 4-methyl = 65 +/- 5 / 35 +/- 5. That single ratio is the upstream variable behind the crystallisation point and the viscosity, so it is worth asking for by name when two lots of the same CAS behave differently in the plant.
Why the CAS number does not fix the product
CAS 11070-44-3 is registered as tetrahydromethylphthalic anhydride: a methyl-substituted tetrahydrophthalic anhydride with the methyl position unspecified. A single positional isomer has its own number – 4-methyl-1,2,3,6-tetrahydrophthalic anhydride is 3425-89-6, listed as PubChem CID 98496 – and PubChem has no record that maps 11070-44-3 to a single structure.
This is the single most useful fact in the file when buying MTHPA. The CAS number, the molecular formula and the molecular weight are identical across grades that differ by 15 deg C in crystallisation point and by a factor of two in viscosity. A specification that reads “MTHPA, CAS 11070-44-3” therefore does not describe a material; it describes a family. The numbers that define the material are the crystallisation point, the viscosity, the colour and the free acid, and a serious specification states all four.
The same point applies to identity testing. Since the formula and the molecular weight cannot separate the grades, arrival inspection has to be built on the physical and titrimetric numbers – crystallisation point, viscosity, anhydride group content, acid value – and on chromatographic isomer distribution where the application justifies it. Elemental analysis will confirm the formula and nothing else.
Reading a Certificate: Three Numbers That Should Agree
An MTHPA certificate normally carries an anhydride group content, an acid value and sometimes a calculated equivalent weight. They are three views of one quantity, and a certificate where they disagree is worth a question.
The anhydride group C2O3 weighs 72.02 g/mol. In a pure 166.17 g/mol molecule that group is 72.02 / 166.17 = 43.34% of the mass. A specification of 41.0% min is therefore 41.0 / 43.34 = 94.6% of theory, and the equivalent weight that follows is 166.18 / 0.946 = 175.7 g/eq, not the 166.18 that appears on every data sheet.
The acid value reaches the same place from the other direction. One anhydride group consumes two equivalents of potassium hydroxide, so the theoretical acid value is 2 x 56.106 / 166.17 x 1000 = 675.4 mg KOH/g. The 640 mg KOH/g floor quoted in the specification is 640 / 675.4 = 94.8% of theory – within a rounding of the 94.6% that the anhydride group number states. That agreement is what a self-consistent specification looks like.
Two things follow, and both matter at goods-in. First, the 685 upper limit is 101.4% of theory, so it cannot be read as a purity ceiling; it is the top of a titration window. Second, the 40.5% minimum that appears on some grades cannot be true at the same time as the 640 acid value floor, because 40.5% of theory works out to an acid value of about 631. When a certificate shows 40.5% and 640 together, one of the two numbers is rounded – which is normal – but a lot that genuinely sits at 40.5% will titrate below the acid value floor.
The hydrolysis arithmetic in acid anhydrides: free acid, colour, iron and moisture runs the same way for the liquid: every 0.1% of water taken up converts anhydride to diacid and moves the free acid figure by roughly one point, so a free acid result is a moisture history record rather than a raw-material property.
Anhydride Curing and the Dose
The formula, and the 15% jump from THPA
phr = (AEW / EEW) x 100 x r where AEW is the anhydride equivalent weight, EEW the epoxy equivalent weight and r the anhydride-to-epoxy ratio, normally 0.85 to 1.00. The full treatment, including blends and diluted resins, is in anhydride curing agent dosage: phr, AEW and accelerators; the epoxy side of the same arithmetic is in epoxy equivalent weight: calculating cure ratios.
| Anhydride | MW | AEW used | phr at EEW 185, r = 0.90 |
|---|---|---|---|
| 1,2,3,6-THPA | 152.15 | 152.15 | 74.0 |
| 3,4,5,6-THPA | 152.15 | 152.15 | 74.0 |
| HHPA | 154.16 | 154.16 | 75.0 |
| MTHPA at theoretical content | 166.17 | 166.18 | 80.9 |
| MTHPA at the 41.0% floor | 166.17 | 175.7 | 85.4 |
The bottom three rows are the point. The two tetrahydrophthalic isomers and HHPA sit within 1.3% of each other, so a dose carried over between them survives. MTHPA sits 9% to 15% above them, and the spread inside MTHPA itself – theoretical against floor – is another 5.3%. A 74 phr line moved to MTHPA without recalculation is 13% short of the anhydride it needs.
Accelerators and the cure profile
Anhydride cure is slow without help. Typical accelerators are tertiary amines such as benzyldimethylamine, substituted imidazoles and quaternary ammonium salts; latent systems for one-pack products are a separate family, compared in dicyandiamide versus other latent curing agents. Casting systems usually cure between 120 and 160 deg C with a post-cure to develop the final glass transition.
The reaction is not strongly exothermic, and that is the reason liquid anhydride dominates thick sections. A 100 mm casting that would run away on an amine system cures through on an anhydride system with a controlled ramp, at the cost of a longer cycle and a heated mould.
Why thick sections choose a liquid
A solid anhydride has to be melted and held hot before it can be metered, and every hour at temperature costs colour and adds free acid. A liquid grade is dosed at ambient or slightly elevated temperature, which removes the melt stage, removes the wet melt-line failure mode, and shortens the batch cycle. The trade is that a liquid is opened, poured and partly used, so the moisture exposure per drum is higher than for a sealed bag of flake.
Applications and What Each One Asks of the Grade
| Application | What the grade has to deliver |
|---|---|
| Dry-type transformer and instrument transformer casting | Low free acid and stable colour; viscosity in the 30 to 50 mPa.s band for vacuum impregnation |
| Potting of power modules, coils and sensors | Long pot life, low volatiles to avoid voids, consistent viscosity batch to batch |
| LED and optical encapsulation | Pt-Co colour at 20 or below, free acid at 0.1 to 0.2%, no yellowing after cure |
| Electrical laminates and prepregs | Consistent viscosity and low volatiles; free acid controlled because it changes the impregnation bath |
| Composite tooling and filament winding | Long gel time, low viscosity at shop temperature, crystallisation point low enough for an unheated store |
Two of these rows are the reason the grade list is long. Colour and free acid are the two numbers that fail first in service, and they are the two that a general-purpose grade does not control tightly. The application-side detail is in electronic and optoelectronic grade MTHPA; the grade-by-grade decision table is in MTHPA grades.
Colour and Free Acid: The Two Numbers That Fail First
Colour in a liquid anhydride is quoted in Pt-Co (Hazen) units, not in Gardner, and that matters when comparing quotes: a Gardner number and a Hazen number for the same liquid are different scales, and a “pale yellow” description with no number is not a specification at all. Pt-Co 50 is a light yellow; Pt-Co 20 is nearly water-white; Pt-Co 10 is the level at which the cured part no longer carries a visible tint.
Free acid is the other axis. In a liquid it behaves differently from a solid: the surface-to-volume ratio is fixed by the drum, but every opening exchanges the headspace with the plant air, and a drum that is opened weekly over a year accumulates water that a sealed bag never sees. This is why the electronic grades are specified at 0.1 or 0.2% and why the same grades are normally shipped under nitrogen.
Iron is the third number, and it is the one that explains most colour complaints: a light-coloured liquid stored in an unlined carbon-steel drum will pick up iron and darken. The colour specification and the packaging specification are the same requirement stated twice.
Storage, Handling and Re-melting
Store above the crystallisation point of the grade. A 0 deg C grade in an unheated northern store will crystallise, and a crystallised drum is not a damaged drum – but the crystals and the remaining liquid are not the same composition, so the drum must be melted completely and homogenised before sampling. Sampling a partly crystallised drum is the most common way to get a free acid result that cannot be reproduced on the next delivery.
Re-melt in a controlled oven or with a drum heater at the lowest workable temperature, never with an open flame or a direct high-temperature band heater. Heat history shows up as colour drift, and colour drift in a light-coloured grade is not recoverable. Keep bungs closed, and blank with dry nitrogen after partial use where free acid is specified below 0.5%.
Segregate from amines, alkalis, alcohols and water; the anhydride reacts exothermically with amines and hydrolyses with water. Gloves and eye protection are the minimum – the material is a skin sensitiser and the hydrolysis product is a corrosive diacid. Spills should be absorbed dry and never washed into a drain with water.
Buying Checklist and How to Write the Specification
- CAS plus four numbers. CAS 11070-44-3 on its own does not define the product. State crystallisation point, viscosity at 25 deg C, colour in Pt-Co and free acid.
- Anhydride group content or equivalent weight. Ask which figure the supplier’s dose recommendation is based on. A certificate at 41.0% implies an AEW of 175.7, not 166.18.
- Isomer ratio. Declared at 3-methyl / 4-methyl = 65 +/- 5 / 35 +/- 5 for the grades on this page, although it is a producer declaration rather than a certificate line. It is the upstream variable that explains the crystallisation point and viscosity, so it is worth having in writing when a formulation is being frozen.
- Volatiles and water. Volatiles at 1.5% max is the stated limit; for vacuum casting, ask for the test method, because the result depends on temperature and time.
- Ion content for electronic use. Chloride is not on the standard certificate but is reported on request, and the current figure is below 2 ppm – low enough that chloride is no longer the limiting ion for an optoelectronic grade. Other ions are measured on request.
- Packaging and blanketing. Drum lining, nitrogen blanket and pallet quantities belong in the purchase order, not in the conversation.
Two neighbours are worth pricing at the same time. Methylhexahydrophthalic anhydride (MHHPA) is the fully hydrogenated analogue – no ring double bond, better colour stability, lower viscosity, and the subject of its own MTHPA vs MHHPA comparison – and methyl nadic anhydride is the higher-temperature option, described in nadic anhydride. Where the resin side is being re-examined at the same time, the viscosity and glass transition trade-off of reactive diluents is in reactive diluent versus epoxy monomer, and the standard resin reference is bisphenol A diglycidyl ether.
FAQ
Is MTHPA a single compound or a mixture?
A mixture. The commercial product is built from the Diels-Alder addition of isoprene to maleic anhydride and contains the 3-methyl and 4-methyl isomers together with a small amount of residual tetrahydrophthalic anhydride. The mixture is the product, and the crystallisation point is the number that records its composition.
Why is the equivalent weight 175.7 on a certificate when the molecular weight is 166.17?
Because the molecular weight describes a pure molecule and the specification describes a material at 41.0% anhydride group content, which is 94.6% of the theoretical 43.34%. The equivalent weight is the molecular weight divided by that active fraction.
Can MTHPA be used instead of THPA without other changes?
The chemistry is the same and the cure schedule is similar, but the dose is not. At EEW 185 and r = 0.90 the figure moves from 74.0 phr to 85.4 phr, so a direct substitution leaves the system roughly 13% short of anhydride. Recalculate from the certificate and re-check the gel time.
Does a 50 to 70 mPa.s grade cure differently from a 30 to 50 grade?
Not through the anhydride chemistry – the equivalent weight is the same. The difference is in processing: fillers settle more slowly in the higher-viscosity grade and the impregnation behaviour of a laminate bath changes. Change the grade without telling the process engineer and the first symptom is usually an air void, not a cure problem.
How do I stop a drum from crystallising in winter?
Buy the -15 deg C grade, or keep the store above 5 deg C. If a drum does crystallise, melt it completely and homogenise before use; do not top up a partly crystallised drum with fresh material, because the two fractions will not mix to the specified composition.
References and Further Reading
- CAS registry entry for 11070-44-3: tetrahydromethylphthalic anhydride; EINECS 234-290-7.
- Single-isomer reference: 4-methyl-1,2,3,6-tetrahydrophthalic anhydride, CAS 3425-89-6, PubChem CID 98496, molecular formula C9H10O3, molecular weight 166.17.
- Anhydride group C2O3 = 72.02 g/mol; potassium hydroxide 56.106 g/mol – the basis of the anhydride group content, acid value and equivalent weight conversions used above.
- PolyBlueChem: MTHPA product page with the seven specifications.
- PolyBlueChem: free acid, colour, iron and moisture in acid anhydrides; anhydride dose calculation.
Contact PolyblueChem for a current certificate of analysis, a sample of any grade, and technical data on isomer ratio and ion content for electronic applications.